Equipment Model :BTS-5V1mA Battery Testing Equipment Equipment Item Code:CT-4008W-5V1mA
Project index |
Parameter index |
Input Power |
AC 220V ±10% / 50Hz |
resolution |
AD:16bit;DA:12bit |
Input Resistance |
≥1MΩ |
Input Power |
0W |
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
Channel Control Mode |
Channel Control Mode |
Voltage |
Per Channel Voltage Range |
25mV-5V |
Accuracy |
± 0.1% of range(Full-scale) |
Stability |
± 0.1% of range(Full-scale) |
Current |
Per Channel Current Range |
0.005mA-0.001A |
Accuracy |
± 0.1% of range(Full-scale) |
Stability |
± 0.1% of range(Full-scale) |
Power |
Per Channel Output Power |
0.005W |
Stability |
± 0.2% of range(Full-scale) |
Time |
Current Response Time |
The Current gets to 3A Hardware Response Time is 20ms |
Step Time Range |
1min ≤Single Step Time Range≤365*24 h,
Time Form Support 00:00:00(h、min、s) |
Data Recording |
Record Condition |
Time△t:(1s ~60000s) |
Voltage△U:(25mV~5V) |
Current△I:(0.005mA~0.001A) |
Record Frequency |
1Hz |
Charge |
Charge Mode |
Constant Current Charge、Constant Voltage Charge、
Constant Current and Constant Voltage Charge |
End Conditon |
Voltage、Current、Relative Time、Capacity |
Discharge |
Discharge Mode |
Constant Current Discharge、Constant Power Discharge |
End Condition |
Voltage、Current、Relative Time、Capacity |
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
Nested Loop |
Nested loop Function,Max Support 3 Layers |
Protection |
Software Protection |
- Power-down Data Protection; NULL
|
- Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time
|
Voltage and Current Testing Sample |
4-wire connecting |
Noise |
<85dB |
Communication way of host computer |
RS232 |
Data Output |
EXCEL、TXT、Graph |
Communication Interface |
Serial port (RS232) |
Per Unit Main Channels No. |
8 |
Dimensions |
1U W*D*H 480*230*48mm
|
Equipment Working Environment
Project index |
Parameter index |
Working Temperature Range |
0℃~40℃ |
Storage Temperature Range |
-10℃~50℃ |
Working Environment Relative Humidity Range |
≤ 70% RH ( no coagulation of vapor) |
Storage Environment Relative Humidity Range |
≤ 80% RH ( no coagulation of vapor) |
Equipment Picture |
|
Picture for Reference Only, take the material object as the standard. |
BTS4000 Software/Hardware Connection
1、Neware battery testing system, before you use BTS-4000battery tester, install the hardware as below picture:
2、Install the softwareBTS7.5.4 , please make sure:
1: turn off the windows firewall(if it's running, you can turn it off from the 'control panel'-'administrative tools'-'services'-'windows firewall', turn it off) and try connection again.
If connected successfully, please ignore the following steps.
2: If it doesn't work or the firewall isn't running.
Please find the services of MySQL and neware bts, make sure they are running.
3、 Make sure the IP of your computer and the middle machine are in the same network segment. Generally, the default IP address of our middle machine would be 192.168.1.x, so please make sure to set up the IP of your computer also to 192.168.1.x. This is very important.
4、Then you can start up the software, if you can see nodes like BTS78/79/80 under the IP address, which means the connections work well.
Now you can map the channels and start up the tests!
Step 1: Start software, you’ll notice none of the functions can be used before you log into the client account. Choose from menu “user -> User Login” and log into the system with user name‘admin’ and password ‘neware’.
Step 2: Right click in the main working area, choose “reset map”.
Step 3: From the popped-up “Set mapping” window, double-click the last node, the relevant channel will appear.
Step 4: Drag the channel one by one to the right window with the mouse. If there are too many channels,click right on the right working area, then choose “The Main Channel Default Mapping->1*8”, and all the channels will be mapped successfully.
Step 5: Right click and choose “Save Map”, then the data of channel mapping will be saved.
Step 6: Return back to the main interface of the BTS software,all the channels of the equipment can be seen. And you can start test by right clicking on any of the channels.